Download document () of 20
We make what matters work
Hydraulic and lubrication filters

VS6 Sensor

The VS6 electronic sensor is used to monitor differential pressure in hydraulic system continuously with 4-20mA signal as well as 2 PNP switch signals.

Clogging indicator type
Electrical
Suitable for
Hydraulic and lubrication systems
Differential Pressure Range
1.5, 2.5, 5.0 bar

Core features

  • Electronic differential pressure sensor
  • Continuous monitoring of differential pressure
  • Output in 4-20mA and 2x PNP signals
  • Thermal lock-out at 25°C
  • M12 connector with 3 integrated LEDs
Specifications

Highlight differences
Show only differences
Hide blank features

Specifications

max. operating pressure:

6,000 psi (stainless steel)

3,200 psi (aluminium)

max. pressure difference: 2,320 psi
operating temperature: -4°F…176°F
temperature range of fluid:

-13°F…212°F (NBR)

14°F…212°F (FPM)

other temperature ranges on request

cold start suppression: < 77°F ± 37.4°F
power voltage: +24VDC ±10%
output signal:

Pin 2, analogue signal:
,Δp: 4...20mA
3mA by cold start suppression


Pin 3 & 4, digital signal:
75% and 100% from Δpnominal as 24VDC
max. 200mA at closed state,
NO by cold start suppression

error of measurement: ± 5% v. Δpnominal by 77°F
protection: IP67